Move database and config from homeassistant /config to addon /config (#16337)

* Move database and config from homeassistant /config to addon /config

* Re-implement config migration for the add-on

* Align some terms

* Improve function name

* Use local variables

* Add model.path migration

* Fix homeassistant config path

* Ensure migration scripts run before go2rtc and frigate

* Migrate all files I know

* Add ffmpeg.path migration

* Update docker/main/rootfs/etc/s6-overlay/s6-rc.d/prepare/run

Co-authored-by: Josh Hawkins <32435876+hawkeye217@users.noreply.github.com>

* Improve some variable names and organization

* Update docs to reflect addon config dir

* Update live.md with /addon_configs

* Move addon config section to configuration doc

* Align several terminologies and improve text

* Fix webrtc example config title

* Capitalize Add-on in more places

* Improve specific add-on config dir docs

* Align bash and python scripts to prefer config.yml over config.yaml

* Support config.json in migration shell scripts

* Change docs to reflect config.yml is preferred over config.yaml

* If previous config was yaml, migrate to yaml

* Fix typo in edgetpu.md

* Fix formatting of Python files

* Remove HailoRT Beta add-on variant from docs

* Add migration for labelmap and certs

* Fix variable name

* Fix new_config_file var unset

* Fix addon config directories table

* Improve db migration to avoid migrating files like .db.bak

* Fix echo location

---------

Co-authored-by: Josh Hawkins <32435876+hawkeye217@users.noreply.github.com>
This commit is contained in:
Felipe Santos
2025-03-24 09:05:59 -05:00
committed by GitHub
co-authored by Josh Hawkins
parent 1e45f63a7c
commit f8b0329b37
41 changed files with 265 additions and 159 deletions
+4 -4
View File
@@ -104,9 +104,9 @@ cameras:
WebRTC works by creating a TCP or UDP connection on port `8555`. However, it requires additional configuration:
- For external access, over the internet, setup your router to forward port `8555` to port `8555` on the Frigate device, for both TCP and UDP.
- For internal/local access, unless you are running through the add-on, you will also need to set the WebRTC candidates list in the go2rtc config. For example, if `192.168.1.10` is the local IP of the device running Frigate:
- For internal/local access, unless you are running through the HA Add-on, you will also need to set the WebRTC candidates list in the go2rtc config. For example, if `192.168.1.10` is the local IP of the device running Frigate:
```yaml title="/config/frigate.yaml"
```yaml title="config.yml"
go2rtc:
streams:
test_cam: ...
@@ -121,9 +121,9 @@ WebRTC works by creating a TCP or UDP connection on port `8555`. However, it req
:::tip
This extra configuration may not be required if Frigate has been installed as a Home Assistant add-on, as Frigate uses the Supervisor's API to generate a WebRTC candidate.
This extra configuration may not be required if Frigate has been installed as a Home Assistant Add-on, as Frigate uses the Supervisor's API to generate a WebRTC candidate.
However, it is recommended if issues occur to define the candidates manually. You should do this if the Frigate add-on fails to generate a valid candidate. If an error occurs you will see some warnings like the below in the add-on logs page during the initialization:
However, it is recommended if issues occur to define the candidates manually. You should do this if the Frigate Add-on fails to generate a valid candidate. If an error occurs you will see some warnings like the below in the Add-on logs page during the initialization:
```log
[WARN] Failed to get IP address from supervisor