track where each camera's detect resolution came from

The health tab's stream check told users to set the detect resolution whenever a probe returned no size, even when they had already set it, and a camera running on the 1280x720 fallback after a failed startup probe was never flagged unless the stream check was run by hand. The config now records whether the resolution came from the config, a startup probe, or the fallback, and /api/config exposes it per camera. The stream check skips the probe warning when the resolution is set, a camera on the fallback gets a detect settings warning that also shows on the health tab, and cloning detect from a fallback camera no longer copies the fallback size.
This commit is contained in:
Josh Hawkins
2026-11-28 18:20:38 -06:00
parent bd90051a15
commit 63807d753c
13 changed files with 209 additions and 4 deletions
+2
View File
@@ -336,6 +336,8 @@ def config(request: Request):
for cmd in camera_dict["ffmpeg_cmds"]:
cmd["cmd"] = clean_camera_user_pass(" ".join(cmd["cmd"]))
camera_dict["detect_resolution_source"] = camera.detect_resolution_source
# masking misses vendor-specific credentials in paths and args, and the
# non-admin UI never reads them
if not is_admin: